Tested to ANSI/UL 60950-1, CAN/CSA C22.2 No. 60950-1-03* and EN 60950-1
Patented Short Circuit and Overload Protection
Ltd power source output allows for Class 2 wiring
Multiple Input Voltages 120V, 240V, and 277V, 50/60 Hz.
Output adjustable for 24VDC max 40W
Dimmable with standard dimmers
No external fusing required
Tested to handle short circuits of over 15 days
Transformer protected against the elements
ETL certified for North America and CE for Europe
Tested to ANSI/UL 60950-1, CAN/CSA C22.2 No. 60950-1-03* and EN 60950-1
Patented Short Circuit and Overload Protection
Ltd power source output allows for Class 2 wiring
Multiple Input Voltages 120V, 240V, and 277V, 50/60 Hz.
Output adjustable for 12VDC or 24VDC max 60W
Dimmable with standard dimmers
No external fusing required
Tested to handle short circuits of over 15 days
Transformer protected against the elements
ETL certified for North America and CE for Europe
Max load 100W
Transformer itself enclosed in the enclosure
Input leads are 20AWG • Output leads are 12 AWG (12V) & 16 AWG (24V)
Lead insulation is 221º F • Transformer uses Class B 266º F insulation
Enclosure temperature does not exceed 158º F @ 104º F ambient temperature
2 knockouts for 3/4” screw cable connectors
Enclosure is black powder coated
Has manual reset thermal circuit breaker on secondary side
Can be controlled with a low-voltage dimmer
ETL Listed
Max load 150W
Transformer itself enclosed in the enclosure
Input leads are are 20AWG (12V) & 18AWG (24V)
Output leads are 12 AWG
Lead insulation is 221º F • Transformer uses Class B 266º F insulation
Enclosure temperature does not exceed 158º F @ 104º F ambient temperature
2 knockouts for 3/4” screw cable connectors (4 knockouts 24V).
Enclosure is black powder coated
Has manual reset thermal circuit breaker on secondary side
Can be controlled with a low-voltage dimmer
ETL Listed
Max load 200W
Transformer itself enclosed in the enclosure
Input leads are are 20AWG (12V) & 18AWG (24V)
Output leads are 12 AWG
Lead insulation is 221º F • Transformer uses Class B 266º F insulation
Enclosure temperature does not exceed 158º F @ 104º F ambient temperature
2 bottom knockouts for 3/4” screw cable connectors.
Enclosure is black powder coated
Has manual reset thermal circuit breaker on secondary side
Can be controlled with a low-voltage dimmer
ETL Listed
Max load 300W
Transformer itself enclosed in the enclosure
Input leads are are 18AWG
Output leads are 12 AWG
Lead insulation is 221º F • Transformer uses Class B 266º F insulation
Enclosure temperature does not exceed 158º F @ 104º F ambient temperature
4 knockouts for 3/4” screw cable connectors
Enclosure is black powder coated
Has manual reset thermal circuit breaker on secondary side
Can be controlled with a low-voltage dimmer
ETL Listed